Need help? Email us: sales1@arc-components.com

SW92-12 Albright 2 x 12V SW80 Single-acting Contactors On A Double Bracket - Intermittent

£78.23 Excl. VAT
(£93.88 Inc. VAT)
Earn 78 Loyalty Points
   
Pre-order
Despatch: 8 to 10 Weeks
Model
SW92-12
Bar Code
DNA
Part Number
SW92-12
Brand
Albright
Colour
Black
Voltage
12V DC
Amperage
100A
Material
Plastic/Bakelite/Brass/Copper
Coil type
Intermittent
Ship Weight
750 g
 

 Pre-orders and back-ordering are available for all Albright brand out-of-stock items, with a current lead time of approximately 8 to 10 weeks despatch.

  • Ordering more Albright brand products than is shown in stock will put your order into a backorder process.
  • Request "Ship all available" in the order comments section if you order more units than are available.

 Telephone: +44 (0) 1924 823119 or Email us to discuss further requirements.


 Albright SW92-12, 2 x SW80 12Vdc single-acting solenoid contactors on a double bracket, intermittent.

  • The SW92 has been designed for direct current loads.
  • Developed for both interrupted and uninterrupted loads,the SW92 is suitable for switching Resistive, Capacitive and Inductive loads.
  • Repair contact kit for a single coil is part number: 2070-57, you require 2 x to service both contactors on the SW92.
  • Auxiliary switch kit for a single coil is part number: 2070-124, you require 2 x for the SW92, 1 switch per SPST coil.
  • 6 inch (minimum) flying coil leads fitted.
  • One link accross positive terminal.
  • ONE LINK ACROSS POSITIVE TERMINAL. COIL LEADS 6 INCHES LONG (MINIMUM).

Dimensions

  • Height, including terminals and coil base cap: 94mm.
  • Coil width: 41mm.
  • Cap width: 50.5mm.
  • Cap depth: 39mm.

About Intermittent (Int.) SW92 Solenoids

 Intermittent contactors, by design, are predominantly used for hydraulic functions on vehicles; they make and break quicker than continuous solenoids and are not recommended for prolonged contact periods.

 The SW92 features single pole double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity. The SW92 has M8 stud main terminals and 6.3mm spade coil connections. Mounting using the supplied bracket, can be horizontal or vertical, when vertical the M8 contact studs should point upwards.

Interrupted Current: The opening and closing on load with frequent switching (resulting in increased contact resistance).
Uninterrupted Current: No or infrequent load switching requirements (maintains a lower contact resistance).

Specifications

Device Type
2 x NO - SP - ST
Voltage
12V D.C.
Coil Type
Intermittent
Amps
100 Amps
Coil Resistance (Ohms)
9
Pull In Voltage (V)
8.0 Max.
Drop Out Voltage (V)
3.5 Max.
Coil Power Dissipation (W)
16.0
Typical Pull-In Time
20ms
Typical Voltage Drop Per Pole
Across New Contacts At 100A
< 40mV
Operating Ambient Temperature
-40 to +60℃
Guideline Weight
350g
Application
Interrupted
Uninterrupted
Thermal Current Rating
100A
125A
Intermittent Current Rating
 
 
30% Duty
185A
230A
40% Duty
160A
200A
50% Duty
140A
175A
60% Duty
130A
160A
70% Duty
120A
150A

 


Delivery
 
UK Mainland Postage

Delivery Options Our Free UK Mainland Postage and Packaging Service offers unbeatable value for money. The free UK Standard shipping is automatically applied to your shopping cart page with no additional cost when you reach the £50.00 minimum order value.

 We use Royal Mail Standard or Recorded Delivery for light, low-value orders and we use FedEx, UPS, Parcel Force, and other major courier services for larger and more valuable consignments.

 
International Consignments

 Our international customers will need to provide the exact Card Holder Address (Invoicee) as the first address for payment processing. Please note that PO Box addresses are not acceptable as delivery addresses by some couriers. All export orders must be placed and paid for online. Proforma Bank Transfer IBAN and SWIFT payment methods are available to create online.

Also Bought

Customer Feedback (0)
Leave a Review