SW88-69 Albright Double Acting Reversing Solenoid 12V Continuous
Pre-order Despatch: 9 to 12 Weeks |
Weight: 1.01 kg
Model: SW88-69
Bar Code: DNA
Part Number: SW88-69
Brand: Albright
Colour: Black
Voltage: 12V DC
Amperage: 100A
Material: Copper/Silver/Bakelite
Coil type: Continuous
Pre-order and back-ordering are available with a current 9 to 12 week lead time. Telephone: +44 (0) 1924 823119 or Email us to discuss further requirements. |
SW88-69 double acting strapped pair solenoid contactor 12V continuous.
- Double acting strapped pair 12 Volts DC contactor for motor reversing.
- The SW88 series of contactors has been designed for direct current loads, particularly motors as used on small electric vehicles such as light industrial trucks, powered invalid cars, etc.
- The contactors are compact in size and are fully serviceable, with a range of spare parts available.
- Repair contact kit part number: 2070-151.
- Auxiliary switch kit part number: 2070-124 (1 kit does 1 x coil).
Dimensions
- Height including terminals and coil base cap: 94mm.
- Coil width including bars: 119mm.
- Cap width: 2 x 39mm.
- Total depth including bracket: 55mm.
About the Continuous SW88-69 Reversing Contactors
Continuous contactors by design are predominantly for drive functions on vehicles; they make and break slower than intermittent solenoids, and are recommended for prolonged contact periods.
The SW88 is a configuration of two SW84 type contactors on a common bracket for motor reversing. The SW88 features single pole double breaking main contacts with silver alloy tips, which are weld resistant, hardwearing and have excellent conductivity.
The SW88 main contact circuit, designed for motor reversing, is such that it has a built in failsafe, so that if both coils are energised simultaneously the contact arrangement is open circuits.
The SW88 has M8 stud main terminals and 6.3mm spade coil connections. Mounted using the supplied bracket, mounting of the solenoids can be horizontal or vertical, when vertical the M8 contact studs should point upwards.
Interrupted current - opening and closing on load with frequent switching (results in increased contact resistance). |
Uninterrupted current - no or infrequent load switching requirements (maintains a lower contact resistance). |
Specifications
Device Type | SW88, 2 x SW84 type contactors on a common bracket |
Voltage | 12V D.C. |
Coil Type | Continuous |
Amps | 100A |
Coil Resistance (Ohms) | 14 |
Pull-In Voltage (V) | 8.5 Maximum |
Drop Out Voltage (V) | 3.5 Maximum |
Coil Power Dissipation (W) | 10.29 |
Typical Pull-In Time | 20ms |
Typical Voltage Drop Per Pole Across New Contacts At 100A | Normally Open: 40mV Normally Closed: 50mV |
Operating Ambient Temperature | -40 to +60℃ |
Guideline Weight | 960kg |
Application | Uninterrupted |
Thermal Current Rating | 100A |
Intermittent Current Rating: |
30% Duty | 185A |
40% Duty | 160A |
50% Duty | 140A |
60% Duty | 130A |
70% Duty | 120A |
Free UK Mainland Postage and Packaging Free UK Mainland delivery discount is selectable on your shopping cart page; a £50.00 minimum order value is applicable for the Free Delivery Service, with a variable low Standard Rate shipping charge for smaller consignments. Despatch methods for Standard and Free UK Delivery Service include light, low-value orders despatched via Royal Mail standard or recorded delivery, with large and high-value orders despatched via UPS and Parcel Force courier services. |