Need help? Email us: sales1@arc-components.com

0-856-66 Durite 24V Modified Wave Voltage Inverter 110V Output - 1500W

0-856-66 Durite 24V Modified Wave Voltage Inverter 110V Output - 1500W
0-856-66 Durite 24V Modified Wave Voltage Inverter 110V Output - 1500W
0-856-66 Durite 24V Modified Wave Voltage Inverter 110V Output - 1500W
0-856-66 Durite 24V Modified Wave Voltage Inverter 110V Output - 1500W
£476.26 Excl. VAT
RRP £541.20 Excl. VAT
Initial Savings
£64.94
(£571.51 Inc. VAT)
Earn 476 Loyalty Points
   
Available
Model
0-856-66
Bar Code
5056119130591
Part Number
0-856-66
Brand
Durite
Colour
Red
Material
Aluminium/Copper/Brass/Plastic
Wattage
1500W
Input Voltage
24V DC
Output Voltage
110V AC
Weight
5.12 kg
 

  Durite 24Vdc 1500W modified wave voltage inverter with 110 Volts ac output for industrial on-site field service engineer's work van, including factory and store development site work.

  • Input: 24Vdc (22V to 33Vdc ±1.5V).
  • Output: 110Vac 50Hz.
  • It is rated at 1500 watts (1.5kW), continuous.
  • Quiescent (inactive) current less than 0.60A.
  • Remote available to purchase separately, part number: 0-856-98

Protection Against

  • Overload.
  • Over-temperature.
  • Low battery.
  • High input voltage.
  • Short circuit.

Supplied With

  • A 3-Pin 110V socket outlet to BS4343.
  • On-Off switch.
  • LED indicators for voltage and consumption.

Dimensions

  • Length: 240mm.
  • Width: 408mm.
  • Height: 76mm.

Warnings for Translation

  • Read all instructions before attempting to install or use the inverter.
  • High voltage, 110 volts ac, is generated by this unit.
  • Do not use it with wet hands or near water.
  • This unit is only suitable for 24-volt electrical systems with negative earth.
  • To supply 110 volts 50 Hz loads of < 1500 watts.
  • Do not connect to any other ac power source.

Installation Instructions

 Disconnect all battery leads, -ve leads first, before installing the inverter.

 Locate a suitable position for the inverter and fit it securely. The site chosen should be:

  • Well ventilated.
  • Not exposed to direct sunlight or heat source.
  • Away from water or moisture.
  • Out of reach of children.
  • Away from any flammable or heat-sensitive substance.

 Connect the Black 24 volts -ve terminal to the negative side of the supply source and the Red 24 volts +ve terminal to a fused positive supply source. Use a minimum of 16.0mm² cable and keep all cable runs as short as possible.

 Connect the inverter case ground terminal to the chassis ground when installing in a vehicle, the vessel’s grounding system in a boat or to earth in a fixed location. The case ground terminal is connected to the ground terminal in the ac outlet socket.

 If using an additional remote control (part number to purchase: 0-856-98), fix the remote control in a suitable position and insert the connector into the remote control socket on the inverter control panel.

Operating Instructions

  1. Ensure that the inverter is supplied by a 24-28 volt dc negative earth system and that the load requires <1500 watts at 110 volts 50Hz ac.
  2. Plug the appliance into the inverter and then turn on the inverter’s power switch. The LED will illuminate to indicate ac power is present, then switch on the appliance. Always turn on the inverter before turning on loads individually. If using the optional remote control, ensure the control panel power switch is set to ‘Remote’, then use the remote ‘On/Off’ switch as the inverter power switch.
  3. Switch off the inverter when not in use or when heavy current is drawn from the dc supply, e.g. when starting an engine from the same supply source.
  4. Battery voltage and current bar graphs indicate supply voltage and current. In normal operation, the inverter will operate in the green region. The inverter can operate in the current yellow zone for short periods, and a protective shutdown will occur if used in the red zone.
  5. If the inverter beeps but is still supplying ac output, this indicates a low supply voltage; switch off the inverter to preserve battery voltage. If left on, the inverter will automatically shut down when the supply voltage falls to approximately 20.0 ± 1.0 volts.
  6. The overtemp indicator illuminates when the inverter has shut down due to overheating. The inverter will restart automatically once it has cooled down.
  7. The overload indicator illuminates when the inverter has shut down due to output short-circuit or gross overloading. If this occurs, switch the inverter off and correct the cause before switching the inverter on again.

Troubleshooting

 If the inverter beeps or does not appear to be functioning correctly, check the following:

  1. Low dc supply voltage, supply voltage <21 .0 ± 1.0 volts.
  2. Low dc voltage shutdown, supply voltage <21.0 ± 1.0 volts.
  3. Overload shutdown, check load requirement is <1500 watts. The warning signal is constant short beeps, and a continuous tone indicates shutdown.
  4. Thermal shutdown, switch off, allow the inverter to cool down and reduce load.
  5. Wiring, terminals and connections.

Specifications

DC Input
24Vdc (22V to 33Vdc ± 1.5V)
AC Output
110Vac
Output Frequency
50Hz
Output Waveform
Modified Wave
Continuous Output Power
1500 watts
Surge Output Power (5 seconds)
3000 watts
Efficiency
90 Percent Max
Regulation
± 5 Percent
No Load Current
Less than 0.6A
Battery Low Voltage Alarm
21 ± 1 Vdc
Battery Low Voltage Shutdown
20 ± 1 Vdc
Overtemp Protection
60 +/- 5 degrees C
Outlet
Single 3-Pin Yellow 110V socket
Cooling Fan
Yes
Short Circuit Protection
Yes
Overload Protection
Yes
Dimensions
240mm x 433mm x 76mm
Net Weight
4.6Kg

 


Delivery
 
UK Mainland Postage Offer

Delivery Options Our Free UK Mainland Postage and Packaging Service offers unbeatable value for money. The free UK Standard shipping is automatically applied to your shopping cart page with no additional cost when you reach the £50.00 minimum order value.

 We use Royal Mail Standard or Recorded Delivery for light, low-value orders and we use FedEx, UPS, Parcel Force, and other major courier services for larger and more valuable consignments.

 
International Consignments

 Our international customers will need to provide the exact Card Holder Address (Invoicee) as the first address for payment processing. Please note that PO Box addresses are not acceptable as delivery addresses by some couriers. All export orders must be placed and paid for online. Proforma Bank Transfer IBAN and SWIFT payment methods are available to create online.

Also Bought

Customer Feedback (0)
Leave a Review