0-205-11 Durite 170A Heavy Duty Slave or Jump Lead Set 5M

£84.31  Excl. VAT
  (£101.17 Inc. VAT)
RRP:  £101.58
Savings before Cart:  £17.27
Earn 84 Loyalty Points
Available

Weight:  4.17kg


Model:  0-205-11
Bar Code:  5056119106350
Part Number:  0-205-11
Brand:  Durite
Colour:  Black/Red
Amperage:  170A
Material:  Copper/PVC


 Set of heavy duty slave leads 5M long with inline connectors.

  • Set of heavy duty slave leads 5M long.
  • 322 strand 0.30mm, 25mm² cable.
  • 170A rated cable.
  • PVC insulated cable.
  • With plated steel crocodile clips.
  • Fitted with 0-431-75 connectors at 1M inline.

Safety Instructions for Jump Starting (For lost copies or translation)

  WARNING: Read these instructions in full before attempting to use the jump leads. Before connecting the jump leads ensure that the following safety measures are adhered to.

  • Batteries give off flammable gases - do not smoke or use naked flames.
  • Ensure that both batteries are of the same nominal voltage. Battery or charging system damage or explosions can result if jump starting is attempted with batteries of differing voltage.
  • Ensure that the two vehicles are not touching each other; sparks and vehicle damage could result if they are.
  • Ensure that the jump leads are in good condition; breaks in the conductor or poor connections make starting difficult and can cause overheating and fire.
  • Ensure that the ignition switches of both vehicles are in the off position and that both hand brakes are applied. If the jump leads are connected whilst the ignition is switched on, sparks and fire may result.
  • Always connect the batteries positive (red, +) to positive (red, +) and negative (black. -) to negative (black, -) irrespective of the vehicles' earth terminations.
  • Ensure that both vehicles are in NEUTRAL (for vehicles with manual transmission) or in PARK (for vehicles with automatic transmission).

Procedure for Connecting Jump Leads

  • Connect the jump leads one at a time.
  • Connect the positive lead (red) first.
  • Always attach each jump lead to the charged/donor battery first.
  • Complete both connections of the first lead before making the first connection with the second lead.
  • If the above procedure is followed correctly, the fourth and final connection made will be the earth connection to the discharge battery. Unlike the other connections which are made to the battery terminal post, this final connection shall be made to a good earth point remote from the discharged battery. A suitable earth point may be in engine mounting, chassis member, engine block or any other unpainted surface remote from the battery and away from fuel and brake lines.
  • Start the engine on the donor vehicle and run it for about 1 minute at a fast tick-over, in sub-zero temperatures this time should be extended to 2 minutes or 3 minutes.
  • With the engine of the donor vehicle still running, attempt to start the vehicle with the discharged battery. If nothing happens, switch off the ignition on both vehicles and re-check all connections.
  • After starting the vehicle with the discharged battery, run this engine at a fast tick-over for several minutes to warm-up and then allow to idle. Do not disconnect the jump leads with the engine of either vehicle running at above idle speed: this can cause damage to the charging circuits and to other electronic equipment.

Procedure for Disconnecting the Leads

  • Detach the clip connected to the earth point on the vehicle that had the discharged battery then disconnect the other end of this lead from the donor battery.
  • Disconnect the second lead first from the vehicle that had the discharged battery and then from the donor vehicle.
Free UK Mainland Postage and Packaging

Delivery Options Free UK Mainland delivery discount is selectable on your shopping cart page; a £50.00 minimum order value is applicable for the Free Delivery Service, with a variable low Standard Rate shipping charge for smaller consignments.
 Despatch methods for Standard and Free UK Delivery Service include light, low-value orders despatched via Royal Mail standard or recorded delivery, with large and high-value orders despatched via UPS and Parcel Force courier services.

International Consignments

 International orders and consignments require the exact Card Holder Address (Invoicee) as the first address for payment processing. PO Box addresses are not acceptable as delivery addresses by some couriers.
 Export orders will only be accepted when placed online.


Featured Products
0-534-10 Durite 12V-24V Red LCD Battery Voltage Monitor
0-534-10 Durite 12V-24V Red LCD Battery Voltage Monitor

12V or 24V LED style battery monitor. Panel or bracket mounted gauge with 6.3mm terminals and fits into a 28mm socket.

Reference: 0-534-10 £19.66   £16.32

0-564-02 12V to 48V Reversing Alarm 97dB(A) at 1200Hz
0-564-02 12V to 48V Reversing Alarm 97dB(A) at 1200Hz

Multi-voltage 12-48V reverse/back up alarm, 97dB(A) at 1200Hz, 60 pulses per minute, two position fixing bracket, CE approved.

Reference: 0-564-02 £23.90   £19.84

SW60-37P Albright 12V DC IP66 Sealed Miniature Solenoid Intermittent 80A
SW60-37P Albright 12V DC IP66 Sealed Miniature Solenoid Intermittent 80A

Albright SW60-37P 12V intermittent contactor, designed for a compact DC application, used as a line switch on electric vehicles.

Reference: SW60-37P £15.24
Recently Viewed
NATO NCAGE Supplier Code: U07T3  |  Need help? Email us: sales1@arc-components.com
Arc-Components.com
UK ISO9001 Auto Electrical Parts Specialists